Release Firmware 64-chars D8/D9-2-4-65

Release Firmware 64-chars D8/D9-2-4-65 Features and Bugfixes: With a very special BACnet configuration it could happen that the controller reboots. During the summer/winter time changeover in combination with NTP, time shifts could occur. We have adapted e-mail security to two-factor authentication. We support the following e-mail providers: Gmail, Yahoo Mail, Outlook, GMX, Web.de, Mail.de.In order…

RCO683D-S and RCO693D-S

RCO683D-S und RCO693D-S Dear system partners, unfortunately the 15.4″ touch panel did not make it into our current catalogue. Therefore we present our newest member of the ELESTA family again separately. The RCO693D-S is the big brother of the RCO683D-S. The differences are the larger screen diagonal of 15,6″/39,6cm and the FullHD resolution with 1920x1080px.…

RCO-tool 2.4.6

Dear system partners, a new version of the RCO-tool is available for download in the partner portal. And with the new version of the RCO-tool the Datapointlist is added, which offers many new functions that reduce the workload even more. Datapointlist The Datapointlist with its folder structure provides a much clearer view of all data…

ER445A02 end of life

ER445A02 end of life   Unfortunately we have to inform you that the BACnet single room controller ER445A02 is no longer produced. There are still some items in stock, so there are still spare or replacement devices available. The Modbus RTU RS485 devices RCO ER440A02 and RCO ER450A02 are not affected, they are still available.

release RCO-tool 2.4.5.7000

release RCO-tool 2.4.5.7000 a new version of the RCO-tool is available for download in the partner portal. And with the new version of the RCO-tool, the fully integrated programming is now fully usable. (project size is limited) Fully integrated programming? These are modules in which, for example, a complete heating circuit was realized in only…

Release Firmware 64-chars D8/D9-2-4-60

Release Firmware 64-chars D8/D9-2-4-60 Features und bug fixes: BACnet schedule handling extended. M-Bus time stamp recognition extended. E-mail timestamp information changed. E-mail recipients can be changed during operation, via program. We uploaded an example program in our partner portal Process to recognize insert SD-card was changed. RCO-Web trend, data loading improvments.

Release RCO-view 2.4.5

Release RCO-view 2.4.5 RCO-view 2.4.5 alarm-sound and compatibility with RCO-Tool projects up to version 2.4.5.6000. with the new version of the RCO-view 2.4.5 all RCO-Tool projects up to version 2.4.5.6000 can be loaded to the RCO-view Server. At the RCO-view Web-part an alarm-sound function was implemented. This function triggers an alarm-sound-file as soon as a…